Here are troubleshooting steps for common issues with magnetic high-pressure reactors:

1. **Stirring Speed Not Displayed or Shows "No"**

- **Controller Issue**: If the reactor controller shows no display, it indicates a problem within the controller, requiring inspection by an electrician.

- **Speed Measurement Issue**: If the controller displays "no," the issue may lie with the controller or the speed measurement line, necessitating professional inspection.

2. **Magnetic Stirrer Not Rotating**

- **Motor Check**: Verify if the motor is functioning. If the motor is faulty, replace it.

- **Internal Magnet or Bearing Problem**: If the motor runs but the stirrer doesn't, the issue is likely with the internal magnet or bearings. In this case, the reactor must be sent to the factory for repair.

3. **Temperature of High-Pressure Stainless Steel Reactor Not Rising**

- **Heating Resistor Check**: Inspect the heating resistor for faults.

- **Controller or Wiring Issue**: If the resistor is fine, the problem may be with the temperature control gauge or internal wiring, requiring factory repair or electrician assistance.