Views: 757 Author: LENOTANK Publish Time: 2025-09-24 Origin: Site
### Filtration Quality Issues and Solutions:
1. **Symptom**: Filtration quality does not meet requirements.**Causes**:
- Insufficient filter aid added.
- Short cycle time, leading to uneven adsorption in the filter layer.
- Faulty beverage pump.
- Air inside the filter body and piping not removed.
- Damaged filter cloth and rubber separator.**Solutions**:
- Add sufficient filter aid.
- Increase the cycle time.
- Check and ensure the beverage pump is functioning properly before operation.
- Remove any air from the filter body and piping.
- Inspect and replace the filter cloth and rubber separator if damaged.
2. **Symptom**: Slow filtration.**Causes**:
- Excessive filter aid added.
- Low inlet pressure.
- Overfilled filter mud.
- High fluid viscosity.**Solutions**:
- Reduce the amount of filter aid appropriately.
- Increase the inlet pressure.
- Clean the sludge promptly.
- Reduce the viscosity of the filtrate.
3. **Symptom**: Filter leakage.**Causes**:
- Housing gasket not properly installed or damaged.
- Clamp or handwheel not tightened.**Solutions**:
- Replace or properly install the gasket.
- Tighten the clamp or handwheel securely.
4. **Symptom**: Infusion pump pressure not meeting requirements.**Causes**:
- Pump seal malfunctioning.
- Pump malfunction.
- Suction tube too soft.**Solutions**:
- Replace the pump seal.
- Identify and repair the pump malfunction.
- Use a spring-loaded hose for the suction tube.